kubota zd331 won't shut off

The speed of PTO: 2. ZD 331 - while mowing, if I stop for some reason, shut it off and then restart, engage blades, it will go for a short distance before shaking and running very rough then dying. 2nd, perform a voltage test on the circuit to ensure you have close to battery level voltage to the shutoff solenoid when it activates. With the seat up you should be able to see what has failed. Any injury, damage or loss that may result from improper use of these tools, equipment, or the information contained in this video is the sole responsibility of the user and not Fill's Small Engine Nation.#smallenginerepair #mowerwontturnoff Jun 3, 2009 Messages 7 Location Tennessee Tractor Kubota M7040 4wd I had my Kubota ZD 21 zero turn loaded onto my trailer this afternoon and I went to unload and park it in the barn, but it wouldn't cut off. You must log in or register to reply here. This spring at 300 hours, the engine blew, my guys were not checking oil. I was hoping to be able to just dial in one height for one area and another height for another area as needed without having to adjust the wheels each time any suggestions? L185F, Modern Ag Competitor 4 shredder, Rhino tiller, rear dirt scoop. I mentioned all of the problems it gave me, how I fixed it, and included a picture of the wire that broke. Customer There is no power at shutoff solenoid MowerDocMD, Expert They installed a relay at the starter, I believe he called it a "Grasshopper" kit, that they install a lot of. I have a similar issue with my Zd326p. operation. Well in this video, I will be showing you how to fix a lawn mower that won't shut off when you release the handle. SERVICING AND . I also have (2) 2008 ZD331 / 60" decks that currently have 1600 and 1700 hours respectively. I had to bypass one of the relays in order to start it and have to manually shut the fuel solenoid to turn it off. Usually the relay keeps the solenoid engaged for 10 seconds, or so, to enable the engine to totally shut down. The starter can go bad and that also happens with ZD1211. Established in 2009, we are the largest online community of Kubota tractor and equipment owners. When turning the key to assy. What happened to start this all off ismy dogs were trying to get a chipmunk that was hiding under or in the mower somewhere. 2023 LawnMowerForum.com. Anyone? Satisfied Customers: 44,878. I parked it to change blades, now it will not start. JavaScript is disabled. $$$. Ruled out everything else, so I hope that fixes it. I would just get one loud click from the starter when I turned the key. I can make educated guesses for most of it, but a document to add to my notes would be even better. If it sounds broken, any suggestions as to how to troubleshoot it and or fix it will be greatly appreciated. I can jump the starter and fires right up. Thanks again for your time. Used the manual fuel shut off to stop the mower. 1st, perform a continuity test on the circuit, to ensure you don't have a short. I would suggest checking the battery connections and main engine ground if you have not already done so. You are using an out of date browser. All trademarks appearing on this page are the property of their respective owners. To avoid tip over, operate across the slopes not up and cleaning, or servicing any PTO-driven equipment. Stay off hills and slopes too steep for safe 3. Kubota zd331 I turned the key and the lights went out and now nothing won't start. For a better experience, please enable JavaScript in your browser before proceeding. Replaced it and resolved the problem. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. I've turn the key and get my glow plugs and I've tried to jump the starter to get it started so I can move it from th yard to the garage to work on it. Have a nice day!0:00 Intro0:15 Lawn mower won't shut off1:22 Here's the problem1:46 What I think happened2:19 Repair time3:22 Test our repair3:37 Quick tip3:58 Outro__________________________________________________________Check out our Merchandise storehttps://fsenmerch.creator-spring.com/Join The Facebook Group Today!https://www.facebook.com/groups/smallenginenationFollow Us On Instagram For Behind-The-Scenes Content.https://bit.ly/378nlsRJoin this channel to get access to perks:https://www.youtube.com/channel/UCt-6EvLa9wyzzKKBoEnoIbA/join__________________________________________________________Keep Up With Us! Subscribe To Our Channel: https://bit.ly/32jZJis Hit The Bell To Be Part Of The Notification Squad! Follow Us On Instagram: https://bit.ly/378nlsR__________________________________________________________My Most Used Small Engine Repair Tools6L Ultrasonic Cleaner - https://amzn.to/3n6uTltOregon Spark Plug Tester - https://amzn.to/3kdWmQcMilwaukee 3/8\" Drive Stubby Impact - https://amzn.to/36jilQQMilwaukee 3/8\" Drive Ratchet - https://amzn.to/3eL0Rk6Compression Tester - https://amzn.to/2JVLr1c5 Piece Spark Plug Socket Set - https://amzn.to/36jXAECCarburetor Adjustment Set - https://amzn.to/3dYbO3eStihl Tachometer EDT9 - https://amzn.to/2PuadZtOur EDC Gear Samsung Galaxy S20 Ultra 5G - https://amzn.to/2GC3iJgSelfie Stick Tripod - https://amzn.to/3exHueiSamsung Galaxy Buds+ - https://amzn.to/3l71NldRode Wireless GO - https://amzn.to/3dWn2oIMilwaukee Fastback Utility Knife - https://amzn.to/35g0ESRPodcast Mic - https://amzn.to/2QD9JAz__________________________________________________________Due to factors beyond the control of Fill's Small Engine Nation, it cannot guarantee against unauthorized modifications of this information, or improper use of this information. the fuel pump comes on and the shut off solenoid picks up. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. I checked the trigger wire voltage when cranking and I have 8.6 volts. The ohm meter may verify that everything is okay including the battery cables, it may not start without a jump on a cold start. http://www.tractorbynet.com/forums/all-other-brands/301894-any-toro-groundsmaster-fans-here.html. JavaScript is disabled. You should unbolt is and turn the ignition switch on and off to actuate it and see if it's letting go like it should when not installed. Three premium, high-performance diesel mowers with the quality and versatility to handle a wide range of mowing jobs. Further, that the anti-scalp wheels should be adjusted such that they are not in constant contact with the ground. Easy fix that can be done by most DIY professionals. About a month ago it wouldn't start. Once I got the initial loud click, if I kept turning the key back and forth the gauge lights were very weak and it wouldn't engage the starter or no loud click. You are using an out of date browser. But what gets so disturbing is that even if you replace the starter with a new one, you may still face the starter problem. To shut off the tractor manually just leave the cowl off and hand operate the lever thus starving the engine of fuel. In fact, when I turn the adjustment wheel, there does seems to be almost no resistance in turning the wheel, about an inch in either direction, then I can't turn it any further than those points, almost like it's not engaged at all ie, I don't think it is working. #1 Hello, I am unable to get my ZD331 to start. You have to pull the spark plug to turn off the lawn mower. You are using an out of date browser. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. It has been recently serviced by Kubota dealer. Even the WSM has very little information. I have a 2007 ZD331 72p that ran great last year from august to December. Over the last 5 years I had this original ZD331 / 72" deck that I traded last fall with 1800 hours. Experience: Technican turned service manager on multiple lines of equipment and rental equipment. With your deck raised up, raise your seat and try turning your deck height adjustment knob. A few nights ago I went to start it and got the same thing. It only acts up when it gets to operating temperature. Then I traded my 72" for a 3rd 60" last fall. The 10amp fuse for the controller was blown but still did not work after replacing it. With your deck raised up, raise your seat and try turning your deck height adjustment knob. There are only 2 possible reasons for a shutdown failure: By the way, GSP you may want to follow "Any Groundsmaster fans on here?". Is your mower not shutting off? After running it and getting it to operating temperature sometimes it will not start back up. I swapped relays and still same issue. Thought this might be the best place to post this.I have a 2007 Toro Groundsmaster with a Kubota 28 hp engine (D1105) with 620 hours on it. The starter issue was identical, although I was not able to track down a high resistance connection. Does anyone have any insight on Kubota's Controller? Just ordered the controller, $232 from Kubota. Years later, it failed again, so I rigged up a pushbutton for the kill function. ' When the key was turned the glow plug light came on, but the starter never energized. Do others use the Cutting Height Control successfully? Trying to restart, it will do the same shaking and rough engine before dying. #3. Trying to restart, it will do the same shaking and rough engine before dying. Aug 13, 2017 / cuttiing height dilemma on ZD331. I turned the key to the off position and then removed it completely, but it continued to run. They just started grabbing at anything they could get their teeth on. If I jiggled the positive battery cable it would reset itself and once I turned the key I would again get that one loud click from the starter but it wouldn't engage the flywheel. ZD 331 - while mowing, if I stop for some reason, shut it off and then restart, engage blades, it will go for a short distance before shaking and running very rough then dying. The starter clicks and you can watch the Bendix start to come out but does not fully engage in the flywheel nor does the bendix spin. Problem 1: Wheel and Belt Tension There is no tension on belts and my wheels are squealing when I drive my Kubota ZT282. Well in this video, I will be showing you how to fix a lawn mower that won't shut off when you release the handle. I have an old Kubota riding mower that would not shut off, and it turned out to be the the black box control module. The group has been very helpful to me. This not happening could be the result of a stuck solenoid, a stuck relay or a bad ignition switch. Answered in 2 hours by: Mechanic: Curtis B. Curtis B., Technician. Clogged air filter Bad fuel pump Plugged fuel filter Clogged fuel line Dirty carburetor Bad battery or loose cables Bad safety switch Bad ignition switch Bad recoil Bad ignition coil Faulty charging system Incorrect starting procedure This post may include affiliate links. You will need to check for fuel and/or airflow issues by checking the fuel filter, pump, and lines, as well as the air lines and air filters. Often this ends up with something in the fuel tank that gets sucked down and blocks the fuel outlet of the tank. The mower doesn't want to turn over sometimes after mowing and shutting the mower off. I had the starter rebuilt; replaced the solenoid and the problem still persist. Just a momentary fuel shut off won't do it. Use the PTO with KUBOTA approved attachments. Hope replacing the control box takes care of the problems. I hope you enjoy this video of a lawn mower that will not turn off. NEW ZD SERIES ZD1000 ACSK ubota PRO deck Thanks for this post. There are only 2 possible reasons for a shutdown failure: 1- poor voltage to the fuel shutoff solenoid. Welcome. Sep 12, 2021 Good Morning jwko, welcome to the forum. in this case, the lawn mower is not shutting off because the control bracket is not making contact with the switch stop, thus not grounding out the engine when the handle is released. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. zd326 ZD326P Issues began when the mower wouldn't shut off. I've been going through related problems with 2 Kubota diesels (zd326, 331). Aug 24, 2008. here we go, this will take a second to read. JavaScript is disabled. Waiting 45 minutes may allow the object to move and allow the proper fuel flow. I'm not trying to be mean, but I feel like you didn't read all the way through the post. For a better experience, please enable JavaScript in your browser before proceeding. It's a great thread with experienced owners of Toro Groundsmasters. M9000HDCC3, M9000HD, Kubota GS850 Sidekick. If your wiring harness appears ok, your fuses in-tact and the solenoid is ok then it sounds like a controller problem. For a better experience, please enable JavaScript in your browser before proceeding. You must log in or register to reply here. Fill's Small Engine Nation recommends safe practices when working with power tools, hand tools, lifting tools, jack stands, electrical equipment, blunt instruments, chemicals, lubricants, or any other tools or equipment seen or implied in this video. I have a zd331 kubota and I have a starting issue similar to the ones posted previously. Solution Adjusting belt tension is necessary after 100hrs or 3 months of use depending on what comes first. brought it out for the first time on march 19 08 and it started losing power and missing (289 hours on it). Category: Agriculture and Farm Equipment. You must log in or register to reply here. Now I can't get it to start. Is your mower not shutting off? Quick Fix: Turn On Shut Off Valve, Check Battery Connection and Safety Switch, Set The Shift Lever Problem 2: Kubota ZD331 Fuel Problems Quick Fix: Avoid Using Old, Bad or Dirty Fuel Problem 3: Kubota ZD331 Engine Overheating Issue Quick Fix: Balance a Stable Speed, Refill Coolant and Replace it if Needed I just purchased a 2012 used ZD331 after reading the manual, it appears you are supposed to adjust the cutting height using the Cutting height Control Dial. in this ca. I've been having issues with it starting, so replaced the switch under the brake pedal. Keep first aid kit and fire extinguisher handy at all times. Other than the 45 minute thing it sure sounds like a fuel issue. 2- bad solenoid. ZD Series Kubota's all-new ZD Series of compact and full-size zero-turn mowers have been engineered from the ground up to deliver quality, performance, comfort, and versatility. I contacted the person I purchased it from who is a Kubota dealer and he told me he had contacted some other dealers and was told to use the wheels to adjust the height of the mowing deck, not the Height control dial. but wouldn't have the anti-scalp wheels in contact with the ground continuously? With the seat up you should be able to see what has failed. Is there something I should look further into like the controller? 6. I think when I started the machine without noticing the exposed wiring, some may have shorted out the fuse and possibly the control box. Took it to the dealer and the have worked on it over and over, 19 times since march. But when turning to read more I have the same problem but not a wire. down. You must log in or register to reply here. I have a Kubota ZD331 zero turn mower. JavaScript is disabled. My understanding is use the hydraulic controls to raise the deck, dial in the height you want and then lower the deck and you will have the correct height. If I leave it for about 45 minutes, it will start with no problems and I can finish mowing. Don't forget to hit the like button and subscribe for more videos. This also happen sometimes when you initially go to start the mower. I also noticed that at idle the battery is only charging at 12.8 volts and full throttle it slowly climbs to 14volts. Did you read my post? I thought that by bypassing the seat switch, I would be bypassing the control box but apparently not. (Battery voltage is at 12.20 when cranking) I checked continuity on the trigger wire which goes to the relay and it is good, I also checked continuity from the supply wire of the relay to a connector that looks like goes to the key switch and was good. Ended up replacing the starter and the battery and all was good for the next month. If I leave it for about 45 minutes, it will start with no problems and I can finish mowing. For a better experience, please enable JavaScript in your browser before proceeding. Page 8 SAFE OPERATION 9. Oct 3, 2007 Intermittent problems like yours can be a real pain to find. They have no idea why it quits on me. It may not display this or other websites correctly. Any dealer that tells someone to use their Anti Scalp Wheels as Gauge wheels is a moron. However, when I tried to adjust the height using the Cutting Height Control, I can't see that anything changes. Any dealer that tells someone to use their Anti Scalp Wheels as Gauge wheels is a moron. If your Kubota tractor is starting OK, but then shutting off, you most likely have an issue with fuel starvation. Engine Does Not Stop When Main Switch Is Turned OFF. Well in this video, I will be . Unfortunately, they got a hold of the wires coming from starter area. Every time I turned the key I would get one loud click and then nothing. It may not display this or other websites correctly. Fill's Small Engine Nation assumes no liability for property damage or injury incurred as a result of any of the information contained in this video. Went to mow a few days later and the instrument panel was working (guages) and the fuel pump was energized. Due to factors beyond the control of Fill's Small Engine Nation, no information contained in this video shall create any express or implied warranty or guarantee of any particular result. It may not display this or other websites correctly. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. Mine simply stopped clicking after the trailer ride to the dealer (started working properly).

How To Become Business Analyst, Articles K